fea fea fea fea fea tures tures tures tures tures ? ? ? ? ? can be used to transmit the fcinet ? rs-485 data between a 7200 fire alarm control panel, and up to fifteen (15) distributed intelligent units (diu) via fiber optic cable provides a fiber optic connection between the 7100 and 7200 series fire alarm control panel and multiple annunciators allows a fiber optic cable link between a personal computer, printer or video terminal to 7100 and 7200 series fire alarm control systems over long distances tolerates up to 10 db signal loss between each FLD-1 module fiber optic cable offers high immunity from interference, transients and volt- age spikes ? automatically adjusts to different rs-232 baud rates ? uses industry standard st connectors ? ? fiber optic line driver module . description description description description description the fiber optic line driver module (fld -1) provides fiber optic cable communi- cations between system modules that will be free of ground faults, transients, or noise in- terference. this affords greater reliability and is a more robust application for those instal- lations requiring communications running outdoors between structures. it connects to the rs-232 and rs-485 ports of the fci 7100 and 7200 series fire alarm control panels. the FLD-1 converts either rs-232 or rs- 485 signals to a powerful optical signal that can tolerate a signal loss of up to 10 db. it uses half duplex data flow, an asynchronous protocol, and runs at speeds of up to 19.2 kbps for rs-232 and 128 kbps for rs-485 communications. the FLD-1 is equipped with st connec- tors that will support standard fiber optic cable up to 200 microns (multimode). opti- mal results can be achieved with 62.5/125 micron cable. the FLD-1 provides two modes of opera- tion, the network mode or the point-to-point mode, selectable through dip switch settings on board the FLD-1. network mode network mode network mode network mode network mode using this mode the following configura- tions are possible: FLD-1 specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. however, no re- sponsibility is assumed by gamewell-fci for their use. specifications subject to change without notice. ? 2006 all rights reserved www.gamewell-fci.com 9020-0517 rev. d page 1 of 4 point-to-point mode when configured in the point-to-point mode, a single 7100 or 7200 series control panel may use its rs-232 port to connect to a single printer, video terminal or per- sonal computer (pc) via a fiber optic link. each location requires an FLD-1. installation the FLD-1 module mounts inside its own steel cabinet, which can be located up to 15 feet (4.6 meters) away, using rigid con- duit. the dimensions of the cabinet are 10 1 / 4 ? w x 10? h x 3? d (26.04 x 25.40 x 7.62 cm). operating power for the FLD-1 is obtained from the 7200 or 7100 panel, and is con- nected to the FLD-1 via terminal block. rs- 485 connections are also made via termi- nal block, and rs-232 connections are made using a standard rj-11 cable. an iso 9001 company an iso 9001 company an iso 9001 company an iso 9001 company an iso 9001 company the fci 7200 rs-485 fcinet ? can be exported via panel bus adapter (pba) or local keyboard display unit (kdu\l) from the main panel contain- ing the system control unit (scu) to up to fifteen remotely located kdus, remote annunciator units (raus), and sub-panels containing the distributed intelligent unit (diu). each location re- quires one FLD-1. the rs-485 communication output of the fci 7100 can be converted to an optical link and brought to as many as five remotely located lcd-7100 alphanumeric displays or ldm-7100 remote annunciator drivers. each location requires an FLD-1. a honeywell company
FLD-1 www.gamewell-fci.com fire control instruments FLD-1 pcb 1700-0202 made in usa 4 tb1 23 1 w1 r s - 4 8 5 j1 rxa j3 led3 rs- rs- led4 led1 pnt net- led2 rxa assembly 1120-0820 3 2 1 4 work 232 485 mode rxb txa txb led6 led8 led5 led7 t e r m sw1 o n 1 2 3 4 tb2 txa j2 rxb j5 txb j4 com a com b +24v gnd egnd from j4 connector (txb) of next FLD-1 from j5 connector (rxb) of next FLD-1 to j3connector (rxa) of previous FLD-1 to j2 connector (txa) of previous FLD-1 to rs-232 rj-11 jack of 7200 scu (connector j1) or 7100 bsm (connector j3) to 7100 tb5-1 or 7200 pba tb1-3, kdu tb1-2 or diu tb1-3 to 7100 tb5-2 or 7200 pba tb1-4, kdu tb1-1 or diu tb1-4 to 7100 tb4-2 or 7200 spsu-v tb1-1 or 2 to 7100 tb4-3 or 7200 spsu-v tb1-3 or 4 module layout showing connection points gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 www.gamewell-fci.com specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. however, no responsibility is assumed by gamewell-fci for their use. specifications subject to change without notice. ? 2006 all rights reserved 9020-0517 rev. c / page 2 of 4
FLD-1 www.gamewell-fci.com FLD-1 7200 series control panel w/scu (main control panel) 7200 series distributed system w/diu (sub-system) 7200 series distributed system w/diu (sub-system) fcinet rs-485 from kdu/l or pba (45 ? max. in rigid conduit) FLD-1 FLD-1 rs-232 from scu j1 connector (45? max. in rigid conduit) FLD-1 7200 series distributed system w/diu (sub-system) FLD-1 fcinet rs-485 into diu (45? max. in rigid conduit) fcinet rs-485 into diu (45? max. in rigid conduit) up to 10 db loss up to 10 db loss between each FLD-1 printer FLD-1s set to point-to-point mode keyboard display unit fcinet rs-485 into diu (45? max. in rigid conduit) FLD-1 FLD-1 up to 10 db loss typical 7200 distributed system using FLD-1 modules gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 www.gamewell-fci.com specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. however, no responsibility is assumed by gamewell-fci for their us e. specifications subject to change without notice. ? 2006 a ll rights reserved 9020-0517 rev. d / page 3 of 4
FLD-1 www.gamewell-fci.com ordering informa ordering informa ordering informa ordering informa ordering informa tion tion tion tion tion part number 1100-0429 operating voltage 24 vdc (nominal) @ 0.045 amp (all modes) 32 to 120 f (0 to 49 c) 0 to 85% (non-condensing) asynchronous with half-duplex data flow rs-232 up to 64 kbps rs-485 up to 128 kbps up to 200 microns (multimode), optimized for 62.5/125 microns 10 1 / 4 ? w x 10? h x 3? d (26.04 x 25.40 x 7.62 cm) description operating voltage operating temperature relative humidity protocol speed st connectors dimensions approvals u.l. 864 file s1949 fm approved csfm 07300-0694:251 fcc part 15 model FLD-1 description fiber optic line driver module with back box specifica specifica specifica specifica specifica tions tions tions tions tions point-to-point mode rxa rxb txa txb network mode rxa txb rxb rxa txb rxb rxa txb rxb rxa txb rxb txa txa txa txa gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 www.gamewell-fci.com specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. however, no responsibility is assumed by gamewell-fci for their us e. specifications subject to change without notice. ? 2006 a ll rights reserved 9020-00517 rev. d / page 4 of 4
|